Soft Starter - Dual Pump
FPC-36040-S
- Enclosure:
- IP56 weatherproof rating
- Powder coated mild steel
- Inner door and removable gland plate
- Protection:
- Padlockable mains power isolator switch
- Circuit breaker protected low voltage control and input circuitry
- Individual pump isolation
- Contactor and thermal overload protection of pumps
- Electronic short and overload protection of strobe/buzzer
- Alarms:
- Visual (strobe) and audible (buzzer) alarms
- Control & interface:
- Advanced HMI with backlit LCD screen & navigation keys
- System and pump status overview
- Auto/off/manual operation of pumps
- Alarm display screen and mute button
- Logged data for start & fault counters, pump run hours
- Input configuration and parameter adjustment
- Tank/pit level display (with transducer connected)
- Password protection
- User adjustable soft start and soft stop
- Inputs:
- 1x analogue 4-20mA input for hydrostatic transducer
- 4x digital 24Vdc inputs for float/pressure/flow switches
- Standard terminal configuration: Low level, pump stop, pump start and high level float switches
- Outputs:
- 2x pump supply outputs
- 1x BMS volt free output for common fault
- Modbus RS485 connections
Function Features
- Operation:
- Maximum run timer and auto alternation of pump duty
- Anti seize timer runs pumps periodically during low use
- Optional time out on manual pump mode
- Maximum idle time ensures minimum tank level is maintained
- Staggered pump start and stop
- Pump limiting allows only 1 pump to run at a time
- Static lead pump for applications with low average flows but high peak flows
- Level alarm delay avoiding nuisance alarms
- Current loop reverse operation for maintain pressure or emptying, rather than filling, a tank
- Smart auto silencing and chirp mode alarm
- Fault protection:
- Pump overload shut-down
- High level alarm
- Low level alarm and shut-down
- Low pressure alarm and shut-down (with pressure switch)
- Low flow/prime loss shut-down (with flow switch)
- Optional maximum pump run time shut-down
- Optional transducer fault alarm (with transducer)
Optional Modifications
- 316 stainless steel enclosure
- Free standing enclosure with plinth
- Separate compartment for power authority meters
- Generator input socket and automatic changeover
- Battery backup high level alarm
- 4G SMS alarm sender
- Conductivity relays and probe inputs
- Mains bypass or tank top up control with solenoid valve
Common Applications
- Level Control:
- Submersible sewage
- Submersible storm water
- Transfer pumping
- Pressure control:
- Pressure boosting
FPC-36040-S Range - Three Phase (400Vac)
Code | Power Rating | Enclosure Size |
---|---|---|
FPC-36040-S4.0 | 4.0 kW | 500x500x300mm |
FPC-36040-S5.5 | 5.5 kW | 500x500x300mm |
FPC-36040-S7.5 | 7.5 kW | 500x500x300mm |
FPC-36040-S11 | 11 kW | 500x500x300mm |
FPC-36040-S15 | 15 kW | 500x500x300mm |
FPC-36040-S22 | 22 kW | 600x600x300mm |
FPC-36040-S30 | 30 kW | 600x600x300mm |
FPC-36040-S37 | 37 kW | 600x600x300mm |
FPC-36040-S45 | 45 kW | 800x600x300mm |
FPC-36040-S55 | 55 kW | 800x600x300mm |
FPC-36040-S75 | 75 kW | 800x800x300mm |
FPC-36040-S90 | 90 kW | 800x800x300mm |
Additional Power Ratings up to 160 kW available on request
Contact MATelec Australia for a competitive price and prompt reliable service