Standard Pump Controllers - With Start & Run Capacitors

Standard Range
  • Enclosure:
    • IP56 rated, powder coated mild steel enclosure with inner door and removable gland plate
  • Protection:
    • Pad-lockable mains power isolator switch
    • Circuit breaker protected low voltage control and input circuitry
    • Individual pump isolation
    • Contactor and thermal overload protection of pump motors
    • Din rail mounted terminal connections
  • Control & interface:
    • Single or dual pump keypad interface:
      • Indicator lights for power on, level alarm, pump run and fault
      • Push buttons for alarm mute/reset, pump auto/off/manual control
    • PCB control module with dipswitches for adjusting configuration
    • Visual (strobe) and mutable audible (buzzer) alarms
    • 30μF run capacitor per pump (other capacitor sizes available)
    • 145-174μF start capacitor per pump with adjustable switching timer (only on Start & Run Capacitors version) (other capacitor sizes available)
  • Inputs:
    • Single phase (230Vac) or three phase (400Vac) power supply
    • 4x digital 12Vdc inputs for float or pressure switches, optional low flow switch
    • Standard terminal setup: Low level, pump stop, pump start and high level float switches
  • Outputs:

Function Features

  • High level alarm delay
  • Smart chirp mode alarms
  • Manual pump control
  • Duty sharing and alternation
  • Pump staging and destaging
  • Staggered pump start
  • Level control mode
  • Maintain minimum level
  • Pressure control mode

Fault Protection

  • Pump overload protection
  • Pump anti-seize protection
  • High level alarm
  • Low level alarm 
  • Low flow/prime loss protection
  • Low pressure alarm

Common Applications

  • Submersible sewage
  • Submersible stormwater
  • Pressure boosting

Standard Pump Controllers - With Run Capacitors

Code No of Pumps Phase / Voltage Overload Ratings
FPC-15015 1 1 Phase / 230Vac -AA to -E
FPC-30021 2 1 Phase / 230Vac -AA to -E

Standard Pump Controllers - With Start & Run Capacitors

Code No of Pumps Phase / Voltage Overload Ratings
FPC-15025 1 1 Phase / 230Vac -AA to -E
FPC-30022 2 1 Phase / 230Vac -AA to -E

Overload Rating Guide

Code Suffix Amp Rating
-AA 1.6 - 2.5 Amp
-A 2.5 - 4 Amp
-B 4 - 6 Amp
-BB 5.5 - 8 Amp
-C 7 - 10 Amp
-D 9 - 13 Amp
-E 12 - 18 Amp

Additional overload ratings available on request

Optional Modifications

  • /SMS - With ME-Link module for SMS alarm/status messaging

  • /BBHLS - With battery backup high level alarm
  • /CON - With conductivity relays and inputs for common, stop, start and high level probes
  • /GEN - With generator inlet socket and manual changeover switch
  • /ATS - With automatic generator changeover switch
  • /INT - With intrinsically safe input barrier relay and inputs for working and high level floats
  • Pump thermistor inputs
  • Mine spec enclosure
  • 316 stainless steel enclosure
  • Pump max run time protection
Available