DET-SMK-RF-DC10 Wireless Smoke Alarm Troubleshooting Guide

DET-SMK-RF-DC10

DET-SMK-RF-DC10 WIRELESS SMOKE ALARM TROUBLESHOOTING GUIDE

Troubleshooting guide and other resources for the DET-SMK-RF-DC10 wireless smoke alarm from MATelec Australia.

ACTIVATING THE ALARMS

Activating Your DET-SMK-RF-DC10 Smoke Alarm

The DET-SMK-RF-DC10 features a sealed 10-year lithium battery that automatically activates when the smoke alarm is secured to its mounting bracket.

Follow these steps to activate your alarm and confirm it's operating correctly.

  1. 1

    Before Installation

    If you're installing multiple wireless smoke alarms, complete the pairing process before mounting them in their final positions.

  2. 2

    Activate the Alarm

    Once the mounting bracket has been installed in the required location, position the smoke alarm onto the bracket and rotate it clockwise until fully engaged.

    Attaching the alarm to the bracket automatically activates the sealed lithium battery.

  3. 3

    Confirm Activation

    When the alarm powers on, the red LED will flash once, and the alarm will beep once.

  4. 4

    Check Normal Operation

    Once activated, the red LED will flash briefly every 40 seconds to indicate normal operation.

    Your smoke alarm is now activated and ready for testing.

Activating Your Smoke Alarm

How to Activate MATelec Australia DET-SMK-RF-DC10 Wireless Smoke Alarms

PAIRING SMOKE ALARMS

Pairing your DET-SMK-RF-DC10 Smoke Alarms

The DET-SMK-RF-DC10 supports wireless interconnection of up to 20 compatible smoke alarms within one system. Pairing your alarms allows them to communicate across the wireless network, so when one detects smoke, the interconnected alarms will also sound.

  1. 1

    Before You Start

    Activate each smoke alarm and complete the pairing process before final installation. Once paired, the alarms can be turned off, mounted and reactivated without losing their wireless connection.

  2. 2

    Select the MASTER Alarm

    Choose one smoke alarm to act as the MASTER and identify it using the supplied MASTER sticker.

    Only one MASTER alarm should be used for each installation.

  3. 3

    Enter Pairing Mode

    Quickly press the TEST/HUSH button on the MASTER three times.

    The red LED will flash once per second for up to 10 seconds, then remain solid red to indicate the MASTER is ready to pair.

    The MASTER will remain in pairing mode for up to five minutes.

  4. 4

    Pair Another Smoke Alarm

    While the MASTER is in pairing mode, quickly press the TEST/HUSH button three times on the next smoke alarm.

    One red LED flash and one beep confirm the alarm has successfully joined the MASTER network.

  5. 5

    Add More Alarms

    Repeat the process for each additional smoke alarm, always using the same MASTER.

    Once all alarms have been paired, briefly press the TEST/HUSH button on the MASTER once to exit pairing mode.

  6. 6

    Test the Network

    Test the complete wireless network to confirm all interconnected smoke alarms respond correctly.

Pair Wireless Smoke Alarms

How to Pair MATelec Australia DET-SMK-RF-DC10 Wireless Smoke Alarms

TESTING YOUR ALARM

Testing Your DET-SMK-RF-DC10 Smoke Alarms and Wireless Network

We recommend testing your DET-SMK-RF-DC10 Wireless Smoke Alarms monthly to confirm they are working correctly.

  1. 1

    Test the Smoke Alarm

    Press and hold the TEST/HUSH button until the alarm sounds.

    The red LED will flash once per second, and the alarm will sound its three-beep alarm pattern.

    Quiet Testing Function

    The first three beeps sound at a reduced volume for greater comfort.

    Continue holding the TEST/HUSH button and the next set of beeps will sound at full alarm volume, confirming the alarm is operating correctly.

  2. 2

    Test the Wireless Network

    If the alarm is wirelessly interconnected, release the TEST/HUSH button and confirm the other connected alarms respond.

    The interconnected alarms will sound the three-beep alarm pattern for approximately eight seconds.

  3. 3

    Confirm the Network Test

    Following the test, the red LEDs on the interconnected alarms will flash twice per second for five minutes, confirming they responded to the wireless test.

  4. 4

    Test the Complete Network

    Repeat the test from other smoke alarms as needed to confirm the complete wireless network is operating correctly.

Testing Your Smoke Alarm

How to Test MATelec Australia DET-SMK-RF-DC10 Wireless Smoke Alarms and the Wireless Network

RESETTING THE WIRELESS CONNECTION

Resetting the Wireless Connection on DET-SMK-RF-DC10 Smoke Alarms

If you need to remove a smoke alarm from an existing wireless network, you can clear its connection before pairing it again or changing the network configuration.

  1. 1

    Enter Connect Mode

    Quickly press the TEST/HUSH button three times.

    The red LED will flash for approximately 10 seconds before remaining solid red.

  2. 2

    Clear the Wireless Connection

    While the red LED is solid, press and hold the TEST/HUSH button.

    The red LED will flash for approximately 12 seconds.

  3. 3

    Confirm the Connection Has Been Cleared

    When the alarm sounds one beep, release the TEST/HUSH button.

    The wireless connection has now been cleared.

  4. 4

    Repeat if Required

    Repeat the process for any additional alarms you want to remove from the wireless network.

    Once cleared, the smoke alarm can be paired again as required.

Resetting the Wireless Connection

How to Reset the Wireless Connection on MATelec Australia DET-SMK-RF-DC10 Wireless Smoke Alarms

LED SIGNALS & AUDIBLE ALERTS

LED Signals & Audible Alerts

LED Signals & Audible Alerts Reference Table

Understanding these signals can help you identify when your smoke alarm is operating normally, responding to a smoke event or requires attention.

LED and Audible Signal Reference Guide

Status

LED / Audible Indication

What It Means

Normal Operation

One red flash every 40 seconds. No sound.

Alarm operating normally.

Smoke Alarm Triggered

One red flash per second. Three beeps, pause, repeat.

Smoke detected. Investigate immediately.

Wireless Interconnection Alarm

Three-beep alarm pattern without the red smoke-alarm LED indication.

Alarm responding to a wireless signal from another smoke alarm.

Alarm Memory

Two red flashes every eight seconds for up to seven days. No sound.

Identifies the alarm that initiated a smoke event.

HUSH Mode

One red flash per second for approximately 10 minutes. No audible alarm.

Alarm temporarily silenced.

Wireless Network Test

Three-beep pattern for approximately eight seconds, followed by two red flashes per second for five minutes.

Confirms the alarm responded to a wireless network test.

Low Battery Warning

One red flash and one chirp every 40 seconds.

Replace the complete smoke alarm promptly.

Smoke Sensor Fault

Two red flashes and two beeps every 40 seconds.

Replace the smoke alarm promptly.

End of Life

Three red flashes and three beeps every 40 seconds.

The alarm has reached the end of its service life and must be replaced.

Important: The DET-SMK-RF-DC10 has a sealed battery. If the alarm indicates a low battery, smoke sensor fault or end-of-life condition, the complete smoke alarm should be replaced.

LED Signals & Audible Alerts

Understanding the LED Lights, Beeps and Alarm Signals on MATelec Australia DET-SMK-RF-DC10 Wireless Smoke Alarms

USING HUSH MODE

Using Hush Mode

HUSH Mode allows you to temporarily silence a smoke alarm when you've identified a known nuisance source and confirmed there is no danger.

Important: Always check for signs of smoke or fire before using HUSH Mode. Never assume an alarm is a nuisance alarm without investigating.

  1. 1

    Identify the Initiating Alarm

    If your smoke alarms are interconnected, identify which alarm triggered the event.

    The initiating alarm is indicated by its flashing red LED.

  2. 2

    Activate HUSH Mode

    Once you've confirmed there is no danger, press and release the TEST/HUSH button on the initiating alarm.

  3. 3

    Confirm HUSH Mode Is Active

    The alarm will be silenced for approximately 10 minutes.

    During this time, the red LED will flash once per second to indicate HUSH Mode is active.

  4. 4

    Return to Normal Operation

    After approximately 10 minutes, the smoke alarm will automatically return to normal operation.

    If the condition that triggered the alarm is still present, the alarm may sound again.

Important: Dense smoke can override HUSH Mode and cause the alarm to sound during the silence period.

Using Hush Mode

How to Use HUSH Mode on the MATelec Australia DET-SMK-RF-DC10 Wireless Smoke Alarm

HOW TO IDENTIFY TRIGGERED ALARMS AND CLEAR ALARM MEMORY

How to Identify Triggered Alarms and Clear Alarm Memory in your DET-SMK-RF-DC10 Wireless Network

The DET-SMK-RF-DC10 features a seven-day Alarm Memory function that helps identify which smoke alarm initiated an event within a wireless network.

After a smoke event has ended, the initiating alarm enters Alarm Memory mode.

  1. 1

    Identify the Initiating Alarm

    The alarm that initiated the smoke event will flash its red LED twice every eight seconds for up to seven days.

    The alarm remains silent while Alarm Memory is active.

  2. 2

    Begin Clearing Alarm Memory

    Press and release the TEST/HUSH button once.

    Then press and hold the TEST/HUSH button.

  3. 3

    Wait for the Clearing Sequence

    The alarm will sound for approximately five seconds, followed by the red LED flashing continuously for around 15 seconds.

  4. 4

    Confirm Alarm Memory Has Been Cleared

    When the red LED stops flashing and the alarm beeps, release the TEST/HUSH button.

    Alarm Memory has now been cleared.

How to Identify Triggered Alarms and Clear Alarm Memory

How to Identify Triggered Alarms and Clear Alarm Memory in a MATelec Australia DET-SMK-RF-DC10 Wireless Network

PAIRING THE WIRELESS REMOTE WITH YOUR ALARMS

Pairing the FSA-90000 Wireless Remote with your DET-SMK-RF-DC10 Smoke Alarms

The MATelec Australia FSA-90000 Wireless Remote can be paired with a DET-SMK-RF-DC10 wireless smoke alarm network.

The remote only needs to be paired with the MASTER alarm, rather than each individual smoke alarm.

  1. 1

    Before You Start

    Make sure your smoke alarms are activated and identify the MASTER alarm within the network.

  2. 2

    Activate the Wireless Remote

    Remove the battery isolation tab from the FSA-90000 Wireless Remote.

  3. 3

    Check the Remote's Pairing Mode

    Press the NET button once.

    The LED above the TEST button should illuminate solid red to indicate pairing mode is available.

    Press NET again to exit pairing mode.

  4. 4

    Put the MASTER Alarm into Pairing Mode

    On the MASTER smoke alarm, quickly press the TEST/HUSH button three times within two seconds.

    The red LED will flash 10 times, then remain solid red to indicate the MASTER is in pairing mode.

    The MASTER will remain in pairing mode for up to five minutes.

  5. 5

    Pair the Wireless Remote

    Press the NET button once on the FSA-90000 Wireless Remote.

    When pairing is successful, the MASTER alarm will give one red LED flash and one beep to confirm the connection.

  6. 6

    Exit Pairing Mode

    Briefly press the TEST/HUSH button on the MASTER once to exit pairing mode.

    Your FSA-90000 Wireless Remote is now paired with the DET-SMK-RF-DC10 wireless network.

Pairing the Wireless Remote with your Alarms

Pairing the MATelec Australia FSA-90000 Wireless Remote with MATelec Australia DET-SMK-RF-DC10 Wireless Smoke Alarms

SMOKE ALARM PAIRING INSTRUCTIONS

Pairing your DET-SMK-RF-DC10 Smoke Alarms with Compatible AC Wireless Smoke Alarms

The DET-SMK-RF-DC10 can be paired with compatible MATelec Australia DET-SMK/RF/AC/1 and DET-SMK/RF/AC/10 Wireless Smoke Alarms.

  1. 1

    Before You Start

    Complete the pairing process while the AC smoke alarms are operating on battery backup and before mounting them in their final positions.

  2. 2

    Select the MASTER Alarm

    Choose one DET-SMK-RF-DC10 to act as the MASTER.

    Ideally, select an alarm that will be installed centrally in the home and apply the supplied MASTER sticker for easy identification.

    Only one MASTER alarm is required for each installation.

  3. 3

    Enter Pairing Mode

    Quickly press the TEST/HUSH button on the RF DC10 MASTER three times within two seconds.

    The red LED will flash once per second for up to 10 seconds, then remain solid red.

    The MASTER will remain in pairing mode for up to five minutes.

  4. 4

    Pair the AC Smoke Alarm

    On the DET-SMK/RF/AC/1 or DET-SMK/RF/AC/10, quickly press the TEST/HUSH button three times.

    When the connection is established, both alarms will flash their red LEDs once and emit one beep to confirm pairing.

  5. 5

    Add Additional Alarms

    Repeat the process for each additional compatible smoke alarm.

    Before pairing another alarm, check that the MASTER's red LED remains solid.

  6. 6

    Confirm the Wireless Network

    Once all alarms have been paired, briefly press the TEST/HUSH button on the MASTER once to exit pairing mode.

    Test the complete wireless network to confirm each interconnected smoke alarm responds correctly.

Pairing your Smoke Alarms with Compatible AC Wireless Smoke Alarms

How to Pair a DET-SMK-RF-DC10 Wireless Smoke Alarm with DET-SMK/RF/AC/1 and DET-SMK/RF/AC/10 Smoke Alarms

PAIRING YOUR WIRELESS SMOKE ALARMS WITH FSA-60000 SMOKE ALARMS

Pairing your DET-SMK-RF-DC10 Wireless Smoke Alarms with MATelec Australia FSA-60000 Smoke Alarms

The DET-SMK-RF-DC10 can be paired with compatible MATelec Australia FSA-60000 Smoke Alarms to create an interconnected wireless network.

  1. 1

    Before You Start

    Make sure the RF DC10 is activated and the FSA-60000 has its wireless interconnection module fitted and is ready for pairing.

    Complete the pairing process before mounting the alarms in their final positions.

  2. 2

    Select the MASTER Alarm

    Choose the RF DC10 to act as the MASTER and identify it using the supplied MASTER sticker.

    Only one MASTER should be used for each installation.

  3. 3

    Enter Pairing Mode

    Quickly press the TEST/HUSH button on the RF DC10 MASTER three times within two seconds.

    The red LED will flash once per second for up to 10 seconds, then remain solid red.

    The MASTER will remain in pairing mode for up to five minutes.

  4. 4

    Pair the FSA-60000

    While the RF DC10 MASTER is in pairing mode, press the CONTROL button on the FSA-60000 three times within two seconds.

    When the connection is successfully established, the FSA-60000 will chirp once to confirm it has joined the wireless network.

  5. 5

    Add More Alarms

    Repeat the process for any additional compatible alarms.

    Before adding another alarm, check that the red LED on the RF DC10 MASTER remains solid.

  6. 6

    Confirm the Wireless Network

    Once all alarms have been paired, briefly press the TEST/HUSH button on the MASTER once to exit pairing mode.

    Test the complete wireless network to confirm each interconnected smoke alarm responds correctly.

How to Pair the Wireless Smoke Alarm with FSA-60000 Smoke Alarms

How to Pair the MATelec Australia DET-SMK-RF-DC10 Wireless Smoke Alarm with MATelec Australia FSA-60000 Smoke Alarms

EXPLORE THE DET-SMK-RF-DC10

STILL NEED HELP?

STILL NEED HELP?

Reach out to our trained and qualified technical support for Smoke Alarms.

DET-SMK-RF-DC10 Wireless Smoke Alarm Troubleshooting Guide | MATelec Australia