Jockey/Jacking Pump Controller

MATelec Australia’s Jockey/Jacking Pump Controller is designed to provide control and status indication for a jockey/jacking pump, compliant with the current Australian Standards (AS 2941-2013: Section 5). Housed in a red powder coated metal enclosure, the controller features pump overload protection, a digital input for automatic pump control and an LCD screen/keypad interface with pump status indication, logged data and auto/off/manual control.
Function Features
  • Multi pump control - Control of up to 12 pumps in any number of duty, duty assist and standby pump configurations
  • Pump limiting - For limiting max flow or power requirements
  • Duty sharing and alternation - Adjustable duty change period and bumpless transfer
  • Pump staging and destaging - Additional pumps are staged into operation to maintain setpoint and destaged when no longer required
  • Staggered pump start and stop - Prevents excessive current draw and reduces water surge or hammer
  • Manual pump control - Pump manual mode with ability to override system protections for 15 mins, before reverting back to auto mode
  • System types - Level, pressure, temperature, or flow control modes
  • Control directions - For emptying or filling a tank, boosting or dropping pressure, raising or lowering flow rate, and heating or cooling temperature
  • Pump speed control - Proportional speed control of pumps in level mode, PID speed control with adjustable proportional and integral values to change VSD responsiveness in pressure, flow, and temperature modes
  • Jacking pump control - Pump 1 can be configured as a DOL jacking pump or VSD static lead pump
  • Pressure control mode - Controlled by a 4-20mA pressure transducer and optional backup high-pressure switch
  • Pipe fill - If the system wakes up and pressure is low, pipe fill runs a single pump to gently build pipe pressure and shuts the pump down if unable to build pressure within 10 minutes (Specific to pressure mode)
  • Sleep assist speed minimize - When the system is at setpoint and pump speed is constant due to no demand for water, the system will slowly drop the pump speed, helping it to go to sleep sooner (Specific to pressure mode)
  • Sleep assist boost - When the system is nearing setpoint and there is no demand for water, the system will boost the pressure before going to sleep so it can sleep for longer, reducing pump cycling (specific to pressure mode)
  • Mains bypass valve control - Switches to mains water to bypass supply tank when pumping system is out of water or in a fault condition (specific to pressure mode, available upon request)
  • Level control mode - Controlled by 4-20mA level transducer and optional backup high and low float switches in a tank/pit
  • Well wash valve control - When the system has pumped down to setpoint and the pumps have stopped, the system will open the well wash valve for 5 minutes every 24 hours (specific to level mode)
  • Tank top-up valve control - Tops up tank with mains water when normal inflow of rain or treated water into the tank does not keep up with demand (Specific to pressure and level control, available upon request)
  • Flow control mode - Controlled by a pulse flow meter, with optional backup high and low flow switches
  • Temperature control mode - 4-20mA temperature transducer and optional backup high and low temperature thermostats
  • Auxiliary tank level monitoring - Using an additional level transducer in an auxiliary tank, instead of a backup transducer
  • UV lamp control - Optional UV lamp control for installations that require UV filtering, with adjustable modes
Enclosure
  • IP54 rated, powder-coated mild steel enclosure with removable gland plate
Protection
  • Mains power isolator switch (pad-lockable in the on position)
  • Circuit breaker protected low voltage control and input circuitry
  • Contactor and thermal overload protection of the pump
  • Din rail-mounted terminal connections
Control & interface
  • HMI with backlit LCD screen and keypad:
  • Jacking pump controller PCB control module
Inputs
  • Single phase (230Vac) or three-phase (400Vac) power supply
  • Digital 12Vdc input for pressure switch/pump start signal
Outputs
  • Pump supply output
  • BMS volt-free output for pump fault
Interface Features
  • Main screen with system and pump status, active faults, pump speed and analog level, pressure, flow, or temperature values
  • Individual pump monitoring screen with status, run hours, number of starts, speed, voltage, current, power, and manual control with the ability to override system lockouts
  • Graphical overview screen for monitoring overall system operation
  • Alarm screen with date and time stamped faults
  • Logged data screen with power and water usage graphs, trend graphs for pressure, level, and flow, pump run timers and system event counters
  • System diagnostics screen for easy fault finding, pump rotation testing
  • User-friendly setup wizard for easy commissioning
  • Advanced parameter adjustment
Jockey/Jacking Pump Range 
Code Phase/Voltage Overloads
FPC-70011 1 Phase / 230 Vac -AA to -E
FPC-70013 3 Phase/400Vac -AA to -E

 