Menu
Our Location on Google mapsFollow Us on Linkedin
My Bag

Your bag is currently empty.

Soft Starters   Single Pump

Soft Starters - Single Pump

FPC-15607-S
  • Enclosure:
    • IP56 weatherproof rating
    • Powder coated mild steel
    • Inner door and removable gland plate
  • Protection:
    • Padlockable mains power isolator switch
    • Circuit breaker protected low voltage control and input circuitry
    • Contactor and thermal overload protection of pumps
    • Electronic short and overload protection of strobe/buzzer
  • Alarms:
    • Visual (strobe) and audible (buzzer) alarms
  • Control & interface:
    • Advanced HMI with backlit LCD screen & navigation keys
    • Visual and audible alarm mute/reset/test button
    • System and pump status overview
    • Auto/off/manual operation of pumps
    • Alarm display and reset screen
    • Logged data for start and fault counters, pump run hours
    • Input configuration and parameter adjustment
    • Tank/pit level display (with transducer conencted)
    • Password protection
    • User adjustable soft start and soft stop
  • Inputs:
    • 1x analogue 4-20mA input for hydrostatic transducer
    • 4x digital 24Vdc inputs for float/pressure/flow switches
    • Standard terminal setup: Low level, pump stop, pump start and high level float switches
  • Outputs:
    • 1x pump supply output
    • 1x BMS volt free output for common fault
    • Modbus RS485 connections

Function Features

  • Operation:
    • Anti seize timer runs pump periodically during low use
    • Optional time out on manual pump mode
    • Maximum idle time ensures minimum tank level is maintained
    • Level alarm delay avoiding nuisance alarms
    • Current loop reverse operation for maintain pressure or emptying, rather than filling, a tank
    • Smart auto silencing and chirp mode alarm
  • Fault protection:
    • Pump overload shut-down
    • High level alarm
    • Low level alarm and shut-down
    • Low pressure alarm (with pressure switch)
    • Low flow/prime loss shut-down (with flow switch)
    • Optional maximum pump run time shut-down
    • Optional transducer fault alarm

Optional Modifications

  • 316 stainless steel enclosure
  • Free standing enclosure with plinth
  • Separate compartment for power authority meters
  • Generator input socket and automatic changeover
  • Battery backup high level alarm
  • 4G SMS alarm sender
  • Conductivity relays and probe inputs
  • Mains bypass or tank top up control with solenoid valve

FPC-15607-S Range - Three Phase (400Vac)

Code Power Rating Enclosure Size
FPC-15607-S4.0 4.0 kW 400x400x250mm
FPC-15607-S5.5 5.5 kW 400x400x250mm
FPC-15607-S7.5 7.5 kW 400x400x250mm
FPC-15607-S11 11 kW 400x400x250mm
FPC-15607-S15 15 kW 400x400x250mm
FPC-15607-S22 22 kW 600x400x300mm
FPC-15607-S30 30 kW 600x400x300mm
FPC-15607-S37 37 kW 600x400x300mm
FPC-15607-S45 45 kW 600x400x300mm
FPC-15607-S55 55 kW 600x400x300mm
FPC-15607-S75 75 kW 800x600x300mm
FPC-15607-S90 90 kW 800x600x300mm

Additional Power Ratings up to 160 kW available on request