Menu
Our Location on Google mapsFollow Us on Linkedin
My Bag

Your bag is currently empty.

Standard Pump Controllers

Standard Pump Controllers - Residential Series

Standard Range


  • Enclosure:


    • IP56 rated, powder coated mild steel enclosure with inner door and removable gland plate



  • Protection:

    • Pad-lockable mains power isolator switch

    • Circuit breaker protected low voltage control and input circuitry

    • Individual pump RCD protection (accessible through inner door for safe reset)

    • Contactor and thermal overload protection of pump motors

    • Din rail mounted terminal connections



  • Control & interface:

    • Single or dual pump keypad interface:

      • Indicator lights for power on, level alarm, pump run and fault

      • Push buttons for alarm mute/reset, pump auto/off/manual control



    • PCB control module with dipswitches for adjusting configuration

    • Visual (strobe) and mutable audible (buzzer) alarms

    • Soft starter per pump with adjustable soft start and stop (Soft Start versions)



  • Inputs:

    • Single phase (230Vac) or three phase (400Vac) power supply

    • 4x digital 12Vdc inputs for float or pressure switches, optional low flow switch

    • Standard terminal setup: Low level, pump stop, pump start and high level float switches



  • Outputs:




Function Features




  • High level alarm delay

  • Smart chirp mode alarms

  • Manual pump control

  • Duty sharing and alternation

  • Pump staging and destaging

  • Staggered pump start

  • Level control mode

  • Maintain minimum level

  • Pressure control mode



Fault Protection




  • Earth leakage feedback

  • True pump redundancy

  • Alarms are maintained even if both pumps are faulted 

  • Pump overload protection

  • Pump anti-seize protection

  • High level alarm

  • Low level alarm 

  • Low flow/prime loss protection

  • Low pressure alarm



Common Applications




  • Submersible sewage

  • Submersible stormwater

  • Pressure boosting



Standard Pump Controllers - Residential Series



























Code No of Pumps Phase / Voltage Overload Ratings Soft Starter Ratings
FPC-30028 2 1 Phase / 230Vac -AA to -E N/A
FPC-30048 2 3 Phase / 400Vac -AA to -E -S4.0 to -S90


Overload Rating Guide






































Code Suffix Amp Rating
-AA 1.6 - 2.5 Amp
-A 2.5 - 4 Amp
-B 4 - 6 Amp
-BB 5.5 - 8 Amp
-C 7 - 10 Amp
-D 9 - 13 Amp
-E 12 - 18 Amp


Additional overload ratings available on request



For FLCs greater than 18 Amps, soft starters are recommended



Soft Starter Guide


























































Code Suffix kW Rating
-S4.0 4.0 kW
-S5.5 5.5 kW
-S7.5 7.5 kW
-S11 11 kW
-S15 15 kW
-S22 22 kW
-S30 30 kW
-S37 37 kW
-S45 45 kW
-S55 55 kW
-S75 75 kW
-S90 90 kW


Additional kW ratings up to 160kW available on request



Optional Modifications




  • /SMS - With ME-Link module for SMS alarm/status messaging

  • /BBHLS - With battery backup high level alarm

  • /CON - With conductivity relays and inputs for common, stop, start and high level probes

  • /GEN - With generator inlet socket and manual changeover switch

  • /ATS - With automatic generator changeover switch

  • /INT - With intrinsically safe input barrier relay and inputs for working and high level floats

  • Pump thermistor inputs

  • Mine spec enclosure

  • 316 stainless steel enclosure

  • Pump max run time protection


Available