IP56 rated, powder coated mild steel enclosure with inner door and removable gland plate
Protection:
Pad-lockable mains power isolator switch
Circuit breaker protected low voltage control and input circuitry
Individual pump isolation
Contactor and thermal overload protection of pump motors
Din rail mounted terminal connections
Control & interface:
HydroTOUCH colour touch screen HMI (See interface features)
HydroTOUCH PCB control module
Visual (strobe) and mutable audible (buzzer) alarms
Soft starter per pump with adjustable soft start and stop (Soft Start version)
Inputs:
Single phase (230Vac) or three phase (400Vac) power supply
2x Analog 4-20mA inputs for level, pressure or temperature transducers
Up to 5x digital 24Vdc inputs for float or pressure switches, or thermostats
Digital pulse input for flow meter
Standard terminal setup: Primary and secondary level transducers, backup low and high level floats, and flow input
Thermal switch inputs per pump (three phase only)
Outputs:
1-12 pump supply outputs
BMS volt free output for common fault (additional available upon request)
2x Analog 4-20mA BMS outputs for analog readings
Output for solenoid valve available upon request
Modbus RTU Serial RS485 connections for SCADA
Function Features
Multi pump control - Control of up to 12 pumps in any number of duty, duty assist and standby pump configurations
Pump limiting - For limiting max flow or power requirements
Duty sharing and alternation - Adjustable duty change period and bumpless transfer
Pump staging and destaging - Additional pumps are staged into operation to maintain setpoint and destaged when no longer required
Staggered pump start and stop - Prevents excessive current draw and reduces water surge or hammer
Manual pump control - Pump manual mode with ability to override system protections for 15 mins, before reverting back to auto mode
System types - Level, pressure or temperature control modes
Control directions - For emptying or filling a tank, boosting or dropping pressure and heating or cooling temperature
Pump 1 mode - Pump 1 can be configured as a main pump, jacking pump or a mixer
Pressure control mode - Controlled by a 4-20mA pressure transducer and optional backup high pressure switch
Pipe fill - If the system wakes up and pressure is low, pipe fill runs a single pump to gently build pipe pressure and shuts the pump down if unable to build pressure within 10 minutes (Specific to pressure mode)
Mains bypass valve control - Switches to mains water to bypass supply tank when pumping system is out of water or in fault condition (specific to pressure mode, available upon request)
Level control mode - Controlled by 4-20mA level transducer and optional backup high and low level float switches
Maintain minimum level - Ensures minimum tank level is maintained (specific to level mode, empty direction)
Well wash valve control - When the system has pumped down to setpoint and the pumps have stopped, the system will open the well wash valve for 5 minutes every 24 hours (specific to level mode)
Tank top up valve control - Tops up tank with mains water when normal inflow of rain or treated water into tank does not keep up with demand (Specific to pressure and level control, available upon request)
Temperature control mode - 4-20mA temperature transducer and optional backup high and low temp thermostats
Auxiliary tank level monitoring - Using additional level transducer in auxiliary tank, instead of backup transducer
UV lamp control - Optional UV lamp control for installations that require UV filtering, with adjustable modes
Fault Protection
Protection modes - Most protections feature adjustable modes including alarm (alarm only), lockout (alarm and pump shut-down) and inhibit (pump shut-down, no alarm)
High and low level, pressure or temperature protection - Alarm and/or shutdown on high and low level, pressure or temperature depending on the system type, low pressure and flow feature auto restart attempts
Medium level protection - Provides an additional level alarm before the high or low level is reached
Auxiliary tank level protection - High and low level protection from floats or level transducer in auxiliary tank
Auxiliary high & low temp protection - If using additional temperature device instead of backup transducer (specific to temperature mode)
Pump anti-seize protection - Runs pumps periodically during low use to prevent seizing
Maximum flow protection - Activates after pumps run at max flow for 30mins, protecting the system in the event of a burst pipe
Pump cycle protection - Activates if system goes to sleep but wakes up within 5 seconds, 10 times in a row, due to a faulty non-return valve or similar fault preventing the system from maintaining pressure
Low flow protection - Alarms and/or shuts down pump or system if a pump is running but there is no flow for 30 seconds, with automatic restart attempts before activating a lockout
Analog fault protection - Activates faults if analog inputs fail
Transducer redundancy - Switches to backup transducer if primary transducer fails (if using backup transducer)
Transducer discrepancy - If difference between primary and secondary transducers exceeds a certain amount, system will use the most appropriate input relative to the setpoint to protect system from overshooting
Pump overload protection - Shuts down pumps on overload, with automatic duty alternation
Pump thermal switch protection - For three phase pumps
Filter blocked protection - Protects the system when filters are blocked or faulty
UV fault protection - Protects the system when UV filters are faulty
Interface Features
Main screen with system and pump status, active faults,analog values
Individual pump monitoring screen with status, run hours, number of starts, manual control with ability to override system lockouts
Graphical overview screen for monitoring overall system operation
Alarm screen with date and time stamped faults
Logged data screen with water usage graph, trend graphs for pressure, level and flow, pump run timers and system event counters
System diagnostics screen for easy fault finding, pump rotation testing
User friendly setup wizard for easy commissioning
Advanced parameter adjustment
Optional Modifications
Additional BMS volt free outputs
With ME-Link SMS Module for SMS alarm/status messaging
With rain/mains changeover control module and 12Vdc pulse latching solenoid valve
Generator input socket and manual changeover switch, or automatic changeover
Output for normally closed tank top up or well wash valve
Individual pump RCD protection
316 stainless steel enclosure
Free standing enclosure with plinth
Separate compartments for power authority meter
Battery backup high level alarm
Conductivity relays and probe inputs
Modbus TCP gateway with ethernet port
Common Applications
Water transfer
Tank fill
Sewage pump out
Stormwater pump out
Pressure boosting
Hot water recirculation
Chiller supply