Hydrotouch Pump Controllers

Hardware Features

  • Enclosure:
    • IP56 weatherproof rating
    • Powder coated mild steel
    • Inner door and removable gland plate
  • Protection:
    • Padlockable mains power isolator switch
    • Circuit breaker protected low voltage control and input circuitry
    • Individual pump isolation
    • Contactor and thermal overload protection of pumps
    • Electronic short and overload protection for strobe/buzzer
  • Alarms
    • Visual (strobe) and audible (buzzer) alarms
  • Control & interface:
    • Hydrotouch colour touch screen interface
    • Main screen with system, pump, fault and sensor status
    • Individual pump monitoring screen with status, run hours and number of starts, auto/off/manual control of pumps
    • Graphical overview screen for monitoring system operation
    • Alarm screen with date and time stamped faults
    • Logged data screen with power and water usage graphs, trend graphs for pressure, level and flow, pump run timers and and system event counters
    • System diagnostics screen for easy fault finding, pump rotation testing
    • Easy setup commissioning wizard
    • Advanced parameter adjustment
  • Inputs:
    • 2x analogue 4-20mA input for transducers
    • 3x digital 24Vdc inputs for float/pressure/flow switches
    • 1x digital, pulse input for flow meter
    • Standard terminal setup: Primary and secondary level transducers, backup low level float and high level float
  • Outputs:
    • 1-12 pump supply outputs
    • 5x assignable BMS volt free outputs
    • 2x analogue 4-20mA BMS outputs for analogue readings
    • Modbus RS485 connections

Common Applications

  • Level Control:
    • Water Transfer
  • Pressure Control:
    • Pressure Boosting
  • Temperature Control:
    • Hot Water Circulation
 

Hydrotouch DOL Logo

Hydrotouch DOL Pump Controller

Function Features

  • Operation:
    • Maximum run timer and auto alternation of pump duty
    • Anti seize timer runs pumps periodically during low use
    • Pump 1 can be configured as a main pump, jacking pump or a mixer
    • Maximum idle time ensures minimum tank level is maintained
    • Staggered pump start and stop
    • Pump limiting
    • Static lead pump for applications with low average flows but high peak flows
    • Supply tank level monitoring (if using level transducer in supply tank instead of backup transducer)
    • Manual override timer control when system is in fault shutdown
  • Fault protection:
    • Pump overload and prime loss shut-down
    • Automatic changeover on pump fault
    • High and low level/pressure shut-down
    • Supply tank low level protection
    • Pump cycle protection
    • Transducer redundancy switches to backup transducer if first one fails (if using secondary tansducer)

Optional Modifications

  • 316 stainless steel enclosure
  • Modbus TCP gateway with ethernet port
  • Netbiter remote access
  • Mains bypass, tank top up or well wash control with solenoid valve
  • UV lamp control
  • Generator input socket and automatic changeover

 